- Lamp Holders & Lamp Bases[5]
- Wall Switches[5]
- Electrical Plugs & Sockets[6]
- Push Button Switches[6]
- Electronic & Instrument Enclosures[1]
- Power Distribution Equipment[6]
- HVAC Systems & Parts[1]
- Air Conditioning System[1]
- Cooling System[1]
- Electrical Wires[6]
- Power Cables[6]
- Other Wires[1]
- Instrumentation Cables[2]
- Power Cords & Extension Cords[3]
- Circuit Breakers[6]
- Other Switches[4]
- Contactors[6]
- Rotary Switches[1]
- Time Switches[6]
- Relays[6]
- Auto Relays[1]
- Wall Lamps[6]
- Ballasts[1]
- Power Meters[4]
- Voltage Meters[6]
- Current Meters[6]
- Frequency Meters[2]
- Hydraulic Tools[5]
- Terminal Blocks[2]
- Plastic Tubes[1]
- Insulation Materials & Elements[1]
- Other Hand Tools[3]
- Pneumatic Tools[1]
- Other Telephone Accessories[3]
- Fuse Components[1]
- Cable Ties[1]
- Cable Clips[2]
- Cable Glands[1]
- Transformers[3]
- Contact Person : Mr. LEE ANDY
- Company Name : Wenzhou Elsine Electric Co., Ltd.
- Tel : 86-577-62730207
- Fax : 86-577-62730507
- Address : Zhejiang,Yueqing City,XINGUANG RD ,LIUSHI YUEQING ,ZHEJIANG CHINA
- Country/Region : China
- Zip : 325604
Related Product Searches:XJ11 Phase Failure and Sequence Relay (CCX1 XJ3-D),High Quality,Phase Sequence Relay, Over and under voltage protector,XJ11; CCX1; XJ3-D
1.Protect function:
Over-pressure protecting,low voltage protecting,phase-failure protect,phase sequence protect,voltage imbalance protect. 1). XJ11 Overvoltage / Undervoltage / Phase failure / Phase sequence Protection Relay (hereinafter ‘Protection Relay’) , connected with the switching electrical device (like AC contactor etc.) as the protective circuit to do efficient protection for the breakdown which probably occurred over voltage,under voltage,phase failure,phase sequence in the irreversible 3-phase AC electromotor and transmission equipment( for example water pump,draught fan,conveyer belt,air compressor,feeder line).
2). Protection Relay are widely used in the low voltage power distribution system of using 3-phase 50Hz, AC380V in the industry,agriculture and service.3). Protection Relay can disconnect the power supply of the main circuit to reaching the purpose of protecting the equipment and human safety under the conditions as below: when the phase sequence of Protection Relay is confirmed, wrong connected with the pre-confirmed phase sequence due to change or maintain,occurred phase failure in the supply circuit,occurred over voltage or under voltage in the supply power grid.4). Protection Relay adopts the advanced technique of voltage test and excellent IC as its main parts. Its feature are reliable operation, accurate failure indication, strong anti-interference, small volume, simple installation and use , furthermore it cannot be influenced by the big or small power of been protected equipment.
3. Main technical data1). Power and voltage:,3-phase 380VAC 50/60Hz2). Over voltage protection: 380v-460v can be adjusted, delay time 1.5s-4s can be adjusted.3). Under voltage protection: 300v-380v can be adjusted, delay time 2s-9s can be adjusted.4). Phase failure and phase sequence active time≤ 2s.5). Mechanical time:1×106 times6). Electrical time:1×105 times7). Contact capacity: AC220V 3A(Resistance)8). Power consumption: ≤2W
XJ11 Phase Failure and Sequence Relay (CCX1 XJ3-D)